AFR Teflon wire for installation |
Teflon film covered insulation wire for installation AFR250, AFR200, AFR150, AFR100 |
Type |
Description |
Application |
Insulation Material |
The permissible continuing temperature /¡æ |
Rated Voltage /V |
Nominal cross-section /mm2 |
AFR 100 |
teflon film covered insulation wire for installation |
For line of aerospace£¬electrical appliance, telecommunication equipment and instrument. |
ETFE |
-60 ~ +100 |
110
250
600 |
0.013 ~ 4 |
AFR 150 |
-60 ~ +150 |
AFR 200 |
-60 ~ +200 |
AFR 250 |
-60 ~ +250 |
Nominal cross-section /mm2 |
AWG |
Conductor construction |
Max.OD of cable /mm |
Construction pcs /mm |
Conductor diamm |
AFR |
AFRP |
110V |
250V |
600V |
110V |
250V |
600V |
0.013 |
36 |
7¡Á0.05 |
0.15 |
0.38 |
0.49 |
0.71 |
0.70 |
0.82 |
1.02 |
0.035 |
32 |
7¡Á0.08 |
0.24 |
0.47 |
0.58 |
0.81 |
0.85 |
0.91 |
1.14 |
0.06 |
29 |
7¡Á0.10 |
0.30 |
0.55 |
0.65 |
0.87 |
0.90 |
0.97 |
1.20 |
0.08 |
28 |
7¡Á0.12
19¡Á0.07 |
0.36 |
0.60 |
0.70 |
0.93 |
1.00 |
1.03 |
1.26 |
0.10 |
27 |
7¡Á0.14
19¡Á0.08 |
0.42 |
0.70 |
0.83 |
1.00 |
1.05 |
1.15 |
1.30 |
0.14 |
26 |
7¡Á0.16
19¡Á0.10 |
0.50 |
0.73 |
0.85 |
1.05 |
1.05 |
1.18 |
1.45 |
0.20 |
24 |
7¡Á0.20
19¡Á0.12 |
0.60 |
0.85 |
0.97 |
1.30 |
1.30 |
1.40 |
1.70 |
0.35 |
22 |
7¡Á0.25
19¡Á0.16 |
0.80 |
|
1.20 |
1.50 |
|
1.60 |
1.90 |
0.50 |
20 |
7¡Á0.30
19¡Á0.18 |
0.90 |
|
1.30 |
1.60 |
|
1.70 |
2.00 |
0.80 |
18 |
7¡Á0.37
19¡Á0.23 |
1.10 |
|
1.65 |
1.85 |
|
2.05 |
2.30 |
1.00 |
17 |
19¡Á0.26 |
1.30 |
|
1.88 |
2.00 |
|
2.25 |
2.45 |
1.20 |
16 |
19¡Á0.28 |
1.40 |
|
1.95 |
2.15 |
|
2.38 |
2.55 |
1.50 |
15 |
19¡Á0.32 |
1.60 |
|
2.15 |
2.35 |
|
2.63 |
2.83 |
2.00 |
14 |
19¡Á0.37 |
1.85 |
|
2.40 |
2.60 |
|
2.97 |
3.08 |
2.50 |
13 |
19¡Á0.14
49¡Á0.26 |
2.34 |
|
|
2.95 |
|
3.20 |
3.43 |
3.00 |
12 |
49¡Á0.28 |
2.52 |
|
|
3.10 |
|
3.37 |
3.50 |
4.00 |
11 |
49¡Á0.32 |
2.88 |
|
|
3.52 |
|
|
4.12 |
|
1. silvered, tinned copper wire or bare copper wire
2. PTFE
3. silvered or tinned copper wire braiding |
|